My title page contents

Capicitor Application Issues

Capacitors must be built to tolerate voltages and currents in excess of their ratings according to standards. The applicable standard for power capacitors is IEEE Std 18-2002, IEEE Standard for Shunt Power Capacitors.

Heat as one of most common cause of motor failure

This slide speaks about that how motor operation fails due to heat. how heat affect motors?

Wednesday, 3 September 2014

Basics of Electrical Products

Company Overview

The objective of this course is to provide a high-level overview of the products of Siemens Energy & Automation (SE&A) with emphasis on those products sold by our channel partners. In order to accomplish this objective, it is useful to briefly discuss our parent company, Siemens AG, and how SE&A fits into the Siemens worldwide business structure.
Siemens AG is one of the world’s largest companies and a leading supplier of electrical and electronic equipment and associated services worldwide. From the initial Siemens company, founded in 1 847, Siemens has grown to employ approximately 475,000 employees in 1 90 countries, including over 70,000 employees in the U. S.
Siemens AG offers a broad range of products and services, most of which fit into one of the following categories:
  • Automation and Control
  • Power
  • Transportation
  • Medical
  • Information and Communication
  • Lighting
Siemens AG is headquartered in Berlin and Munich and operates in most countries through regional operating companies. In the United States, however, Siemens has a number of operating companies that each focus on a portion of the total Siemens portfolio of products and services. These U. S.-based Siemens companies operate under the financial umbrella of Siemens Corporation, headquartered in New York.
SE&A, headquartered in Alpharetta, Georgia, is one of the largest of the Siemens U. S.-based operating companies. Most SE&A products and services are associated with automation and control or power distribution and are used in residential, commercial, institutional, and industrial applications. This course provides an overview of SE&A products with emphasis on products sold by our channel partners. It is important to note, however, that a number of SE&A products, systems, and services are beyond the scope of this course.
In order to help you better understand SE&A products, this course will look at where many of our products fit in the flow of energy in sample residential, commercial, and industrial applications. By better understanding where electrical products fit in this flow of energy, you can better understand the physical and electrical requirements of these products.
Keep in mind that the flow of energy from the electric utility will be discussed only briefly in this course because utility power generation, transmission, and distribution products and services are provided by two other Siemens companies, Siemens Power Corporation and Siemens Power Transmission & Distribution.

Basics of Electricity


Elements of an Atom

All matter is composed of molecules which are made up of a combination of atoms. Atoms have a nucleus with electrons orbiting around it. The nucleus is composed of protons andneutrons (not shown). Most atoms have an equal number of electrons and protons.
  • Electrons have a negative charge (-). Protons have a positive charge (+). Neutrons are neutral. The negative charge of the electrons is balanced by the positive charge of the protons.
Electrons are bound in their orbit by the attraction of the protons. These are referred to as bound electrons.

Free Electrons

Electrons in the outer band can become free of their orbit by the application of some external force such as movement through a magnetic field, friction, or chemical action.
These are referred to as free electrons. A free electron leaves a void which can be filled by an electron forced out of orbit from another atom. As free electrons move from one atom to the next an electron flow is produced.
This is the basis of electricity.

Conductors

An electric current is produced when free electrons move from one atom to the next. Materials that permit many electrons to move freely are called conductors. Copper, silver, aluminum, zinc, brass, and iron are considered good conductors.
  • Copper is the most common material used for conductors and is relatively inexpensive.

Insulators

Materials that allow few free electrons are called insulators. Materials such as plastic, rubber, glass, mica, and ceramic are good insulators.
An electric cable is one example of how conductors and insulators are used. Electrons flow along a copper conductor to provide energy to an electric device such as a radio, lamp, or a motor. An insulator around the outside of the copper conductor is provided to keep electrons in the conductor.


Tuesday, 2 September 2014

Types of Relays and Relay Driver Circuit

We have already studied about what is Relay and Relay Operation in the earlier post. Now let us see different types of relays and how to drive the relay. This article describes you the different types of relays like latching relay, reed relay, polarized relay and so on.

Types of Relays:

Here is the list of various types of relays, their working and applications.

1. Latching Relay:

These relays are also called as impulse relay, stay relays or keep relays as they continue the process what they are doing in the last state when the power is switched off. This mechanism can be achieved with the solenoid which operates in ratchet and cam method. In this method power is consumed only for a particular time. Hence these relays are more preferable than other relays. These relays operate in bistable mode. Hence they have two stable states.

2. Reed Relay:

This type of relays is more preferable in contacts. These relays have low switching voltage and current ratings. These are famous because of their switching speeds. You need to keep these relays inside a vacuum or inert gas to protect from atmosphere.

3. Polarized Relay:

Polarized relays work only when the current flows through the coil in one direction. This relay has a diode in series with coil. This diode blocks the current in other direction. The importance is given to this relays based on its sensitivity. They played major roles in telephone exchanges. This relays are also used in telegraphic distortion.

4. Biased Relays:

This relays have a permanent magnet above the armature. This relay is operates when the current through the coil establishes a force which opposes the magnet. If the established force is in the same direction with magnet then relay will not work, even if you apply a large current through the coil.

5. Buchholz Relay:

Generally these relays are used for safety purpose. These relays are used to know the amount of gas present in the large oil filled transformers. These relays produce warning if it senses fast production or slow production of gas in transformer oil.

6. Overload Protection Relay:

As the name indicates, these relays are used to prevent the electrical loads from damages by short circuits and over currents and abnormal voltages. In this relays a heating element is placed in series with the motors. Thus when over heat occurs the heating element which is connected to the motor heats up and in turn releases the spring to operate the contacts of the relay.

7. Solid State Relay (SSR):

As the name implies, these are designed with solid state components. These are high reliable as they do not have any moving objects in their design. The basic element in solid state relay is output switch or a triac but more often back to back SCRs. As there is no moving parts these are used in the applications where sparking is major issue.

8. Solid State Contactor Relay:

These relays provide the features of both SSR relays and contactor relays. These relays designed for the correct on – off cycles and they have good heat sink. As a result these relays have number of advantages.

9. Inverse Definite Minimum Time Relay (IDMT Relay):

This relay works based on induction principle. This relay has copper or aluminium disc which rotates between damping magnet and electro magnet. Fluxes induce the currents in the disc which produce rotational torque. This disc rotates to a point where it operates the contacts that break the circuit and remove the fault connection.

10. Differential Relay:

Differential relays are used to check the Dissimilarity between input and currents. The distinction between currents may be in magnitude or in phase or in both. For good operation magnitude and phase angle variations should be zero. If there is any unbalance between input and output currents then relay will actuate.

Relay Driver Circuit:



Here is the simple NPN Transistor circuit to drive the relay. We can use less power to drive the relay. We have to make sure that base gets enough current to turn on the transistor. If the transistor gets enough base current then the transistor conducts and relay energizes. When there is no base voltage, the transistor is in open thus blocking the current through coil of the relay.
Here the diode 1n4001 or 1n4007 is connected across the relay, used to protect the transistor from damage due to the back emf generated in the relay coils when transistor is in off. Base resistor is used to set current to the base of the transistor.
Now let us see how to choose the value of R1. Say relay needs 50mA current to the coil to pull the armature and assume coil has resistance of 240 ohm. To turn on the transistor the base current should be greater than the collector current divided by current gain hfe. As the BC337 or BC338 has a minimum current gain of 100 at 100mA. So we need to provide the base current of at least 50mA/100 = 0.5mA.
In practice it is better to double the value, say 1mA of base current. If the input voltage Vin is switching between 0V and 12V. Ib = 12/1mA =12K. So it is better to use 10k resistor.

Busbar voltage drop calculation


  • Calculate Voltage Drop for  Bus Bar
  • Select Size of Bus Bar for particular Load
  • Enter Your Sub Panel Details like Load,Line Length


Home Electrical Bill / Energy Consumption / Load Calculator

  • Calculate Electrical Bill of Home
  • Calculate Size of MCCB/MCB for Domestic Load
  • Calculate Electrical Load of Home.


Calculation of voltage drop and cable size for motor/electrical load

  • Calculate Voltage drop of Cable.
  • Calculate  Size of Cable.
  • Calculate Current Capacity of Cable.



Monday, 1 September 2014

Comparison calculator for DOL and Star-Delta Starter

This is a calculater for electrical engineers which will give you information that how motor will react when you will start it  by DOL method and when you will start it by Star-Delta method.